top of page
Still-Water-Background.jpg

Comprehensive results at your fingertips

16-in-1 Full Panel Strips for Water Quality Testing

A high quality comprehensive full panel test for water quality testing. Each unit comes with an easy to use instruction sheet which enables anyone to do a complete and reliable water test from home.

Usage: Perfect for testing drinking water, pools & hot tubs, spas, freshwater, spring water, hydroponics, aquariums, aquaculture, Industrial waste water, science experiments and more.

WTS-1.png
Buy button logo.png
Unknown.png
WTS-4.png
WTS-2.png
  • Blood
    Intended to detect occult blood in urine. Occult blood indicates urological or kidney diseases. Microhaematuria does not affect the colour of urine and is only detectable microscopically or by chemical detection methods. The detection of blood is based on the pseudo-peroxidative activity of haemoglobin and myoglobin, which catalyse the oxidation of an indicator by an organic hydroperoxide and a chromogen to produce a green colour. Intact erythrocytes are indicated by punctual colorations (spots) on the test pad and, haemoglobin and myoglobin by a uniform green coloration. Large concentrations of ascorbic acid may cause lower readings in urine containing occult blood. False positive results are usually caused by residues of peroxide, chlorine or tertiary ammonium compounds used as disinfectants, detergents or cleaning agents. False positives may also be caused by formalin or by the activities of microbial oxidase from urogenital tract infections. The significance of a positive result varies from patient to patient and should be evaluated in the overall clinical assessment of the patient. The colour fields correspond to the following values: neg (negative), approx. 5-10, approx. 50, approx. 300 Ery/μL. Interpretation: When a result falls between values, read to the lowest colour block. Any “trace values” should be reported as negative. Detection range: 5 – 300 Ery/μL.
  • Urobilinogen
    Intended to detect and estimate urobilinogen in urine. Urobilinogen (a bile pigment degradation product of red cell haemoglobin) is used in the diagnosis and treatment of liver diseases and haemolytic disorders. The test principle is based on the coupling of a stabilised diazonium salt with urobilinogen to form a red azo compound. The normal urobilinogen concentration in urine ranges from 0.1 – 1.8 mg/dL (1.7 – 30 μ mol/L). Any value higher than 2 mg/dL (35 μmol/L) is considered pathological. The urinary pH does not affect the test. Traces of formaldehyde in the urine and exposure of urine to light may cause lowered or falsely negative results. Beetroot and drug metabolites which give a colour at a low pH (azo dyes, p-aminobenzoic acid) may cause false positive results. The colour fields correspond to the following values: normal, 2, 4, 8 and 12 mg/dL, or 0 (negative), 0.3, 1.0 and 5.0 g/L. Interpretation: When a result falls between values, read to the lowest colour block. Detection range: 2 – 12 mg/dL (35 – 200 μmol/L).
  • Bilirubin
    Intended to measure the levels of bilirubin conjugates in urine. Measurement of bilirubin and its conjugates are used in the diagnosis and treatment of certain liver and bile diseases. The test for bilirubin is based on the coupling of bilirubin with a diazonium salt under acidic conditions. Normally no bilirubin is detected in the urine even by the most sensitive methods. The slightest discoloration of the reagent area constitutes a positive (i.e. pathologic) result. Concentrations of 0.5 mg/dL and more result in a red-orange peach colour and indicate the early stage of a liver disease. The pH of the urine does not affect the test reaction. False negatives may be produced by metabolites of drugs that give a colour at low pH, by the presence of nitrites and/or ascorbic acid concentrations in excess of 25 mg/dL (1.4 mmol/L). Indoxyl sulphate may also interfere with the interpretation of a negative or positive bilirubin reading. The presence of urobilinogen can enhance the sensitivity of the test field whilst urine indicane may cause atypical coloration. The colour fields correspond to the following values: neg (negative), 1(+), 2(++), 4(+++) mg/dL or neg (negative), 17(+), 35(++), 70(+++) μmol/L. Interpretation: When a result falls between values, read to the lowest colour block. Detection range: 1 – 4 mg/dL (17 – 70 μmol/L).
  • Protein
    Intended to detect the presence of protein in the urine. Identification of urinary protein is used in the diagnosis and treatment of renal diseases. The test is based on the “protein error” principle of the indicator. The test is especially sensitive to albumin and less sensitive to other proteins. Normally, no protein is detectable in the urine of healthy individuals. Trace values (for example values between negative and 30 mg/dL) should be reported as negative. False positive results are obtained with urine of high alkalinity, urine with high specific gravity, and urine containing quinine, polyvinylpyrrolidone (PVP), detergents or quaternary ammonium compounds (disinfectant residue in the urine collection vessel). The colour fields correspond to the following values: neg (negative), 30, 100 and 500 mg/dL, or neg (negative), 0.3, 1.0 and 5.0 g/L. Interpretation: When a result falls between values, read to the lowest colour block. Any “trace values” should be reported as negative. Detection range: 30 – 500 mg/dL (0.3 – 5.0 g/L).
  • Nitrite
    Intended to detect the presence of nitrite in urine. Detection of nitrite in the urine aids in the treatment of urinary tract infections of bacterial origin. The test is based on the principle of Griess’s test and is specific for nitrite. The reaction reveals the presence of nitrite and hence indirectly of nitrite-forming (Gram Negative) bacteria in the urine by a pink discoloration of the test patch. Even a slight pink coloration is indicative of significant bacteriuria. Prolonged urinary retention in the bladder (4-8 hours) is essential in order to obtain an accurate result. A negative result does not preclude a bacterial infection (insufficient incubation, urinary tract bladder infection due to bacteria not containing nitrite reductase). Administration of antibiotics or chemical drugs including vitamin C should be discontinued 3 days before the test. False positive results usually occur with stale urines in which nitrite has been formed by bacterial contamination of the urine specimen and in urines containing dyes such as beetroot and pyridinium derivatives. False negative results can be caused by various factors including vitamin C, low nitrate content diet, bacteria not containing nitrate reductase, significant diuresis, and insufficient incubation time in the bladder. A reaction pad showing red or blue borders should not be interpreted as a positive result. The colour fields correspond to the following values: neg (negative) and pos (positive). Interpretation: When a result falls between values, read to the nearest colour block. Any purple colour (even faint) should be reported as a positive result. Detection range: 0.05 – 0.1 mg/dL or 6.5 – 13 μmol/L
  • Ketones
    Intended to detect ketones in urine. Identification of ketones is used in the diagnosis and treatment of acidosis of ketosis and for monitoring patients with diabetes. Based on the principle of Legal’s test, this test reacts with acetoacetic acid and acetone in alkaline solution to form a violet coloured complex. Normal urine specimens usually yield negative results, however, detectable levels may be observed during physiological stress conditions such as fasting, pregnancy and frequent strenuous exercise. The test does not react with ß-hydroxybutyrate. Sodium-2-mercapto-ethane sulfonate and other substances containing sulfhydryl groups may produce false-positive results. Phenylketones in high concentrations will cause variable colours. Phthalein compounds and anthrachinone derivates interfere with the test by producing a red coloration which may mask the reaction of ketones. The colour fields correspond to the following acetoacetic acid values: neg (negative), 25(+), 100(++) and 300(+++) mg/dL, or neg (negative), 2.5(+), 10(++) and 30(+++) mmol/dL. Interpretation: When a result falls between values, read to the nearest colour block. Detection range: 25 – 300 mg/dL (2.5 – 30 mmol/L).
  • Glucose
    Intended to measure glucose (glucosuria) in urine. Glucose measurement is used in the diagnosis and treatment of carbohydrate metabolism disorders including diabetes mellitus and hyperglycaemia. This test is based on the specific glucose oxidase (GOD) – peroxidise (POD) reaction with a chromogen. Apart from glucose, no other compound in the urine is known to give a positive reaction. It is independent of pH and not affected by presence of ketone bodies. Test reactivity, however, decreases as the SG of the urine increases. Reactivity is inhibited by low temperature. Small amounts of glucose are filtered by healthy kidneys, therefore changes in the coloration of less than 50 mg/dL (2.8 mmol/L) are considered normal. The inhibitory effects of ascorbic acid has been largely eliminated for glucose readings higher than 150mg/dL. Other inhibitory substances include gentisic acid and pH values higher than 5. False positive results are usually caused by residues of peroxide, chlorine or tertiary ammonium compounds used as disinfectants, detergents or cleaning agents. The colour fields correspond to the following values: normal, 50, 150, 500 and ≥1000 mg/dL, or normal, 2.8, 8.4, 28 and ≥ 56 mmol/dL. Interpretation: When a result falls between values, read to the nearest colour block. Repeat the test the following day when “trace values” are reported. Detection range: 50 – 1000 mg/dL (2.8 – 56 mmol/L).
  • pH
    Intended to estimate the pH of urine. Estimation of urinary pH is used to determine the alkalinity or acidity of urine and aids in the monitoring of patients on specific diets. Abnormal urinary pH values relate to many renal and metabolic disorders. Persistently high pH values may be indicative of urinary tract infections. The pH reaction is based on an indicator that changes colour from 5 to 9. The pH of healthy individuals varies between pH 5 and pH 6. Bacterial contamination may lead to false results. The colour fields correspond to the following values: pH 5, pH 6, pH 7, pH 8, and pH 9. Interpretation: When a result falls between values, read to the nearest colour block. Detection range: pH 5 – pH 9.
  • Specific Gravity
    Intended to provide an estimation of renal ability (urine concentration or urine dilution). The specific gravity of urine varies with fluid intake and can be an indicator of certain disorders. Highly diluted urine (SG 1.000) can indicate a failure of the renal concentration ability. Specific gravity can also serve as an indicator of urine tampering when screening for drug abuse. The test reaction is based on a colour change correlating with the concentration of ions present in the urine. This allows for urine density to be estimated between 1.000 and 1.030. The normal value varies between 1.015 and 1.025. Since pH has an influence on the test, the reaction has been optimised for urine with a pH of 6. Highly alkaline urine (pH >8) will yield slightly lower results, while highly acidic urine will yield slightly higher results. The test is not affected by glucose or urea. The colour fields correspond to the following values: 1.000, 1.005, 1.010, 1.015, 1.020, 1.025 and 1.030. Interpretation: When a result falls between values, read to the nearest colour block. Detection range: 1.000 – 1.030.
  • Leucocytes
    Intended to detect leukocytes in urine. A positive leukocyte result indicates an inflammatory disease of the kidneys and the urinary tract and suggests the need for further investigation. The reaction is based on the release of leukocyte esterase from lysed neutrophils, which react with an ester, producing a pyrrole compound. The pyrrole reacts with a diazonium salt yielding a violet colour. Urine from healthy subjects do not contain any leucocytes. Any positive result is to be considered as clinically relevant. The reaction is not affected by bacteria, trichomonads or erythrocytes present in the urine. Formaldehyde (stabilizer) may cause false-positive reactions. If the urine specimen has a pronounced intrinsic colour (for example due to the presence of bilirubin), the reaction colour may be intensified due to an additive effect. False positive results may be caused by contamination with vaginal secretions. Urinary protein excretions > 500 mg/dL and urinary glucose excretions > 2 g/dL may diminish the intensity of the reaction colour, as can cephalexine cephalothine if administered in high daily doses. The colour fields correspond to the following values: neg (negative), approx. 25, approx. 75 and approx. 500 Leukocytes/μL. Interpretation: When a result falls between values, read to the nearest colour block. Trace values should be repeated on the next urine sample. Detection range: 25 – 500 Leukocytes/μL.
bottom of page